當前位置 : NEB >>> NEB/NEBNext UltraShear?/96 reactions/M7634L
NEB/NEBNext UltraShear?/96 reactions/M7634L
  • NEB/NEBNext UltraShear?/96 reactions/M7634L

NEB/NEBNext UltraShear?/96 reactions/M7634L

價格: 試用 市場價: 0.00

貨號: M7634L
品牌: NEB
規(guī)格
數(shù)量
庫存(0)
特別 提示
代購產(chǎn)品:無質(zhì)量問題不接受退換貨,下單前請仔細核對信息。
下單后請及時聯(lián)系客服核對商品價格,訂單生效后再付款。
資深產(chǎn)品顧問
咨詢顧問

全國免費服務(wù)熱線

4000-520-616


  • 自營商城 一站式服務(wù)
  • 廠家直采 剔除溢價
  • 品質(zhì)甄選 正品保證
  • 嚴控流程 只做188精品
  • 極速物流 如約送貨
  • 詳情
  • 使用說明
  • 常見問題
    • View or download extensive performance data in ourData Supplement.

      Enzymatic methods for DNA fragmentation in NGS workflows enable streamlined protocols, improved performance and scalability. However, specialized fragmentation reagents are required for samples for methylation analysis, to ensure that methylation marks are not removed, and for FFPE DNA. NEBNext UltraShear is a novel enzyme mix designed for fragmentation of these sample types that has a fast workflow and improves library preparation and sequencing metrics for DNA methylation studies and FFPE DNA.NEBNext UltraShear is compatible with NEBNext Enzymatic Methyl-seq (EM-seq) (NEB #E7120).NEBNext UltraShear in FFPE DNA sequencing workflows:

      • Improved usable reads
      • Lower artificial mutation frequency

      NEBNext UltraShear for methylated DNA sequencing e.g., EM-seq

      • Higher library yields
      • Improved sequencing metrics
      • Improved CpG Coverage

      Note that for high quality genomic DNA library prep with enzymatic fragmentation, we recommend NEBNext Ultra II FS DNA Library Prep for Illumina (NEB #E7805, #E6177).

      Figure 1: NEBNext UltraShear increases EM-seq™ library yieldsGraph of Yields
      200 ng, 50 ng and 10 ng of NA12878 DNA spiked with control DNA (CpG methylated pUC19 DNA and unmethylated lambda DNA) were fragmented by either NEBNext UltraShear (20 minutes at 37°C) or Covaris® ME220 (350 bp protocol) followed by EM-seq library preparation. Library yields were quantified using Agilent® TapeStation® with the High Sensitivity D1000 ScreenTape®. EM-seq libraries fragmented by NEBNext UltraShear have higher yields than Covaris for the same number of PCR cycles for each input (200 ng = 4 cycles; 50 ng = 6 cycles; 10ng=8 cycles).
      Figure 2: Improved CpG coverage in EM-seq libraries produced using NEBNext UltraShearGrid showing improvement
      200 ng, 50 ng and 10 ng of NA12878 DNA spiked with control DNA (CpG methylated pUC19 DNA and unmethylated lambda DNA) was fragmented by either NEBNext UltraShear (20 minutes at 37°C) or Covaris ME220 (350 bp protocol) followed by EM-seq library preparation. Technical replicates were generated for each input amount. All libraries were sequenced on the same flowcell of an Illumina® NovaSeq® 6000 (2 x 100 bases). 725 million reads were sampled (seqtk) from each library for methylation analysis. Reads were adapter trimmed (fastp), aligned to the GRCh38 reference (bwa-meth), and duplicate marked (Picard MarkDuplicates) before calling methylation using MethylDackel. NEBNext UltraShear and Covaris fragmentation used ahead of the EM-seq workflow yielded a similar number of CpGs (~54 million) at minimum 1X coverage. At minimum 10X coverage, more CpGs are identified when NEBNext UltraShear is used, due to improved library diversity and coverage evenness.
      Figure 3: NEBNext UltraShear with FFPE DNA improves usable readsGraph comparing usable reads
      FFPE DNA was fragmented using NEBNext UltraShear (15 minutes at 37°C), Covaris ME220, Kapa EvoPlus® Kit, Kapa HyperPlus® Kit, Agilent SureSelect® Enzymatic Fragmentation Kit, NEBNext dsDNA Fragmentase® or NEBNext Ultra II FS. All samples were fragmented according to the respective protocols. Fragmentation with NEBNext dsDNA Fragmentase, Kapa kits and the Agilent kit was followed by a bead cleanup and library construction using the NEBNext Ultra II DNA library Prep Kit for Illumina. NEBNext UltraShear and Covaris-sheared samples were followed directly by use of the NEBNext Ultra II DNA Library Prep Kit for Illumina, and NEBNext Ultra II FS samples followed the recommended protocol for library prep. Each library was sequenced using the Illumina NextSeq® 500. 2 million (2 x 76 base) reads were used for this analysis. Reads were aligned to GRCh38 with Bowtie2 and analyzed using samtools flagstats and Picard CollectAlighmentSummaryMetrics. Percent of usable reads (mappable, proper pairs, and non-duplicates reads) were measured for each library and usable reads were averaged for technical replicates (bars represent error between two technical replicates) for all fragmentation methods. FFPE DNA libraries fragmented with NEBNext UltraShear had the highest percent of usable reads and had similar percent usable reads as high-quality DNA libraries (high-quality DNA had a comparable percent of usable reads across all fragmentation methods ≥ 96%; data not shown).
      Figure 4: NEBNext UltraShear with FFPE DNA reduces artificial mutationsGraphs with mutation data
      FFPE DNA was fragmented using NEBNext UltraShear (15 minutes at 37°C), Covaris ME220, Kapa EvoPlus Kit, Kapa HyperPlus Kit, Agilent SureSelect Enzymatic Fragmentation Kit, NEBNext dsDNA Fragmentase or NEBNext Ultra II FS. All samples were fragmented according to the recommended protocols. Fragmentation with NEBNext dsDNA Fragmentase, Kapa® kits and the Agilent kit was followed by a bead cleanup and NEBNext Ultra II DNA library Prep Kit for Illumina. NEBNext UltraShear and Covaris-sheared samples were followed directly by use of the NEBNext Ultra II DNA Library Prep Kit for Illumina, and NEBNext Ultra II FS samples followed the recommended protocol for library prep. Each library was sequenced using the Illumina NextSeq 500. 2 million (2 x 76 base) reads were used for this analysis. Reads were aligned to GRCh38 with Bowtie2. Artificial C to T mutations were calculated with Tasmanian tool for read 1 and 2 and averaged for technical replicates (bars represent error between two technical replicates). The libraries fragmented with NEBNext UltraShear resulted in the lowest C to T artificial mutation frequency compared to other fragmentation methods for FFPE DNA both reads (R1= Read 1 and R2= Read 2).
      Figure 5: NEBNext UltraShear fragments high-quality genomic DNA in a time-dependent manner Chart of time dependent fragmentation
      50 ng human DNA (NA12878) was fragmented for 5–45 minutes at 37°C followed by 15 minutes at 65°C. Fragmentation occurs during the 37°C incubation step of NEBNext UltraShear. The average fragmentation size and pattern (High Sensitivity D5000 ScreenTape on Agilent TapeStation) is based on fragmentation time.
      This product is related to the following categories:
      FFPE DNA,
      DNA Fragmentation & RNA Fragmentation,
      Next Generation Sequencing Library Preparation
    售后保障
    螞蟻淘生物188,秉承螞蟻淘一貫的嚴謹態(tài)度,由螞蟻淘公司專業(yè)人員負責品控、采購、物流、銷售、售后,保障正品優(yōu)質(zhì)。以“快速好省,為科研提供好產(chǎn)品、好價格”為理念,直接鏈接原廠家,從全國各地原制造商嚴格挑選188款科研精品,剔除品牌溢價,188生物新電商,把好的產(chǎn)品帶給科研!? 力求給你最優(yōu)質(zhì)的商品。
  • Q:生物188產(chǎn)品正品保障嗎?
    A:生物188質(zhì)量把控人員具有十年的從業(yè)經(jīng)驗,在業(yè)界享有良好的口碑;自營商城,直接從廠家采購, 自己的團隊負責國際物流和清關(guān),中間沒有第三方,所有流程嚴格把控,100%保證正品,假一罰十。

    Q:下單后可以修改訂單嗎?
    A:下單后的商品付款之前可以修改;訂單付款成功,需要聯(lián)系我們客服進行修改;客服電話:4000-520-616

    Q:可以開發(fā)票嗎?
    A:本網(wǎng)站所售商品都是正規(guī)清關(guān),均開具16%正規(guī)發(fā)票,發(fā)票金額含配送費金額,另有說明的除外。

    Q:商品幾天可以發(fā)貨?
    A:生物188商品,全部現(xiàn)貨銷售,付款后即可發(fā)貨,一般一周內(nèi)送達!

    Q:如何聯(lián)系商家?
    A:有任何問題夠可以電話咨詢我們,全國24小時免費服務(wù)熱線:4000-520-616 或聯(lián)系我們的在線客服QQ:1570468124

    Q:收到的商品少了/發(fā)錯了怎么辦?
    A:同個訂單購買多個商品可能會分為一個以上包裹發(fā)出,可能不會同時送達,建議查看訂單詳情是否是 部分發(fā)貨狀態(tài);如未收到,可聯(lián)系在線客服或者致電4000-520-616。

    Q:退換貨/維修需要多長時間?
    A:一般情況下,退貨處理周期為客戶收到產(chǎn)品一個月內(nèi)(以快遞公司顯示簽收時間為準),包裝規(guī)格、 數(shù)量、品種不符,外觀毀損、短缺或缺陷,請在收到貨24小時內(nèi)申請退換貨;特殊商品以合同條款為準。

何為188

極簡而嚴謹,我們僅銷售188款生物醫(yī)學科研用品,款款都是爆款;因為少所以聚焦,聚焦甄選每一款產(chǎn)品,聚焦服務(wù)每一位客戶!

關(guān)注我們 :

點擊QQ聯(lián)系我們
生物188微信

關(guān)注188微信公眾號

獲取最新優(yōu)惠活動通知
  • 品質(zhì)甄選,正品保證

  • 自營電商,廠家直采

  • 極簡主義,188精品