當(dāng)前位置 : NEB >>> NEB/NEBNext? Ultra? II DNA Library Prep Kit for Illumina?/96 reactions/E7645L
NEB/NEBNext? Ultra? II DNA Library Prep Kit for Illumina?/96 reactions/E7645L
  • NEB/NEBNext? Ultra? II DNA Library Prep Kit for Illumina?/96 reactions/E7645L

NEB/NEBNext? Ultra? II DNA Library Prep Kit for Illumina?/96 reactions/E7645L

價(jià)格: 試用 市場價(jià): 0.00

貨號: E7645L
品牌: NEB
規(guī)格
數(shù)量
庫存(0)
特別 提示
代購產(chǎn)品:無質(zhì)量問題不接受退換貨,下單前請仔細(xì)核對信息。
下單后請及時(shí)聯(lián)系客服核對商品價(jià)格,訂單生效后再付款。
資深產(chǎn)品顧問
咨詢顧問

全國免費(fèi)服務(wù)熱線

4000-520-616


  • 自營商城 一站式服務(wù)
  • 廠家直采 剔除溢價(jià)
  • 品質(zhì)甄選 正品保證
  • 嚴(yán)控流程 只做188精品
  • 極速物流 如約送貨
  • 詳情
  • 使用說明
  • 常見問題
    • The Ultra II DNA Library Prep Kit for Illumina meets the challenge of constructing high quality libraries from ever-decreasing input quantities.The reagents for each step in the library preparation workflow have been reformulated to enable high yield preparation of high quality libraries from 500 picograms to 1 microgram of input DNA. This new generation of NEBNext reagents uses a fast, streamlined, automatable workflow and enables use of fewer PCR cycles while also improving GC coverage. The kit is also compatible with PCR-free workflows and is effective with challenging samples such as FFPE DNA.

      Now also available with optional SPRIselect® beadsfor clean-up and size-selection steps.Advantages
      • Get more of what you need, with the highest library yields
      • Use to generate high quality libraries even when you have only limited amounts of DNA, with inputs as low as 500 pg
      • Prepare libraries from ALL of your samples, including GC-rich targets and FFPE DNA samples
      • Improve yields and quality for target enrichmentapplications
      • Save time with streamlined workflows, reduced hands-on time and automation compatibility, and enjoy the flexibility of kit or module formats

      To learn more about how NEBNext Ultra II addresses lower input amounts and challenging sample types, download our technical note.

      For use with NEBNext Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors DNA Set 1) (NEB #E7395), refer to the Protocols tab for UMI Adaptors-specific guidance.

        NEBNext Ultra II produces the highest library yields and conversion rates from a broad range of input amounts
        A: Libraries were prepared from Human NA19240 genomic DNA using the input amounts and numbers of PCR cycles shown. Manufacturers’ recommendations were followed, with the exception that size selection was omitted.B: Libraries were prepared from Human NA19240 genomic DNA using the input amounts and library prep kits shown without an amplification step, following manufacturers" recommendations. qPCR was used to quantitate adaptor-ligated molecules, and quantitation values were then normalized to the conversion rate for Ultra II. The Ultra II Kit produces the highest rate of conversion to adaptor-ligated molecules, for a broad range of input amounts.
        View additional data on library yield
        NEBNext Ultra II provides uniform GC coverage for microbial genomic DNA over a broad range of GC composition and input amounts
        Libraries were made using 500 pg, 1 ng and 100 ng of the genomic DNAs shown and the Ultra II DNA Library Prep Kit and sequenced on an Illumina MiSeq®. Reads were mapped using Bowtie 2.2.4 and GC coverage information was calculated using Picard"s CollectGCBiasMetrics (v1.117). Expected normalized coverage of 1.0 is indicated by the horizontal grey line, the number of 100 bp regions at each GC% is indicated by the vertical grey bars, and the colored lines represent the normalized coverage for each library.
        View additional data on library quality
        NEBNext Ultra II provides superior yields in PCR-free workflows
        Libraries were generated from 100 ng of Human NA19240 genomic DNA using the library prep kits shown, following manufacturers" recommendations, and with no amplification step. Library yields were determined by qPCR using the NEBNext Library Quant Kit for Illumina. The NEBNext Ultra II Kit produces the highest yields.

        NEBNext Ultra II libraries provide the highest quality sequence data in PCR-free workflows

        LIBRARY KITTOTAL READS% DUPLICATION% MAPPED% CHIMERAS
        Ultra II3,685,0290.0297.001.10
        Kapa Hyper3,679,1360.0297.002.00
        TruSeq PCR-Free3,681,6430.0596.651.38
        PCR-free libraries were generated from 100 ng of Human NA19240 genomic DNA using library prep kits shown, following manufacturers’ recommendations, and with no amplification step. Libraries were sequenced on the Illumina NextSeq 500. Reads were mapped to the GRCh37 reference using Bowtie 2.2.4.This data illustrates that NEBNext Ultra II DNA Library Prep Kit enables high quality sequence data in PCR-free workflows, even with low input amounts.% Mapped:The percentage of reads mapped to human GRCh37 reference.% Duplication:The percentage of mapped sequence that is marked as duplicate.% Chimeras:The percentage of reads that map outside of a maximum insert size or that have the two ends mapping to different chromosomes. NEBNext Ultra II enables construction of high quality libraries from FFPE DNA samples
        FFPE DNADNA INPUT (ng)LIBRARY YIELDS IN ng% MAPPED% MAPPED IN PAIRS% DUPLICATION% CHIMERAS
        Kidney Tumor1713291.596.10.483.0
        Lung Tumor2023290.194.90.424.1
        Liver Normal2069192.694.70.338.6
        Breast Tumor3051491.995.10.374.5
        Libraries were prepared from 17–30 ng of human DNA extracted from the FFPE tissue samples listed, amplified using 10 cycles of PCR and sequenced on the Illumina MiSeq. Reads were mapped to the GRCh37 reference genome using Bowtie 2.2.4.% Mapped:The percentage of reads mapped to Human GRCh37 reference.% Mapped in Pairs:The percentage of reads whose mate pair was also aligned to the reference.% Duplication:The percentage of mapped sequence that is marked as duplicate.% Chimeras:The percentage of reads that map outside of a maximum insert size or that have the two ends mapping to different chromosomes.This data illustrates that the NEBNext Ultra II DNA Library Prep Kit for Illumina enables high quality sequence data, even with low input amounts of FFPE DNA. View additional data from FFPE DNA samples

        NEBNext Ultra II provides superior yields for target enrichment applications.

        For Nimblegen® enrichment, libraries were prepared with 100 ng of Human HG02922 genomic DNA, using NEBNext Ultra II with the NEBNext Adaptor and index primers, or the Kapa Library Preparation Kit Illumina Platforms with the SeqCap® Adapter Kit (Roche). Target enrichment was performed with NimbleGen SeqCap Human Exome v3.For SureSelectXT enrichment, libraries were prepared with 200 ng of Human HG02922 genomic DNA, using NEBNext Ultra II or Kapa Hyper with the NEBNext Adaptor and index primers, or the SureSelectXT Reagent Kit, Illumina (ILM) platforms with Herculase® II Fusion DNA Polymerase. Target enrichment was performed with SureSelect® Human All Exon V6.Manufacturers’ recommendations were followed, including use of the recommended number of PCR cycles for pre- and post-capture. NEBNext Ultra II libraries resulted in the highest post-capture yields for both enrichment workflows.

        View additional data on target enrichment

        Lot Control

        The lots provided are managed separately and qualified by additional functional validation. Individual reagents undergo standard enzyme activity and quality control assays, and also meet stringent criteria in the additional quality controls listed on each individual component page
        This product is related to the following categories:
        DNA Library Prep for Illumina
      售后保障
      螞蟻淘生物188,秉承螞蟻淘一貫的嚴(yán)謹(jǐn)態(tài)度,由螞蟻淘公司專業(yè)人員負(fù)責(zé)品控、采購、物流、銷售、售后,保障正品優(yōu)質(zhì)。以“快速好省,為科研提供好產(chǎn)品、好價(jià)格”為理念,直接鏈接原廠家,從全國各地原制造商嚴(yán)格挑選188款科研精品,剔除品牌溢價(jià),188生物新電商,把好的產(chǎn)品帶給科研!? 力求給你最優(yōu)質(zhì)的商品。
    • Q:生物188產(chǎn)品正品保障嗎?
      A:生物188質(zhì)量把控人員具有十年的從業(yè)經(jīng)驗(yàn),在業(yè)界享有良好的口碑;自營商城,直接從廠家采購, 自己的團(tuán)隊(duì)負(fù)責(zé)國際物流和清關(guān),中間沒有第三方,所有流程嚴(yán)格把控,100%保證正品,假一罰十。

      Q:下單后可以修改訂單嗎?
      A:下單后的商品付款之前可以修改;訂單付款成功,需要聯(lián)系我們客服進(jìn)行修改;客服電話:4000-520-616

      Q:可以開發(fā)票嗎?
      A:本網(wǎng)站所售商品都是正規(guī)清關(guān),均開具16%正規(guī)發(fā)票,發(fā)票金額含配送費(fèi)金額,另有說明的除外。

      Q:商品幾天可以發(fā)貨?
      A:生物188商品,全部現(xiàn)貨銷售,付款后即可發(fā)貨,一般一周內(nèi)送達(dá)!

      Q:如何聯(lián)系商家?
      A:有任何問題夠可以電話咨詢我們,全國24小時(shí)免費(fèi)服務(wù)熱線:4000-520-616 或聯(lián)系我們的在線客服QQ:1570468124

      Q:收到的商品少了/發(fā)錯(cuò)了怎么辦?
      A:同個(gè)訂單購買多個(gè)商品可能會(huì)分為一個(gè)以上包裹發(fā)出,可能不會(huì)同時(shí)送達(dá),建議查看訂單詳情是否是 部分發(fā)貨狀態(tài);如未收到,可聯(lián)系在線客服或者致電4000-520-616。

      Q:退換貨/維修需要多長時(shí)間?
      A:一般情況下,退貨處理周期為客戶收到產(chǎn)品一個(gè)月內(nèi)(以快遞公司顯示簽收時(shí)間為準(zhǔn)),包裝規(guī)格、 數(shù)量、品種不符,外觀毀損、短缺或缺陷,請?jiān)谑盏截?4小時(shí)內(nèi)申請退換貨;特殊商品以合同條款為準(zhǔn)。

    何為188

    極簡而嚴(yán)謹(jǐn),我們僅銷售188款生物醫(yī)學(xué)科研用品,款款都是爆款;因?yàn)樯偎跃劢?,聚焦甄選每一款產(chǎn)品,聚焦服務(wù)每一位客戶!

    關(guān)注我們 :

    點(diǎn)擊QQ聯(lián)系我們
    生物188微信

    關(guān)注188微信公眾號

    獲取最新優(yōu)惠活動(dòng)通知